A Protective Frame for Mobile Work
The M3003 combines a rugged frame with wheels and a foldable pull handle. Put enclosure protection and practical movement at the center of your product selection.
RUGGED PORTABLE POWER / OEM & ODM
Build your portable power product line around the M3003, a 3072Wh LiFePO4 platform with 3000W continuous AC output. Its wheels and foldable pull handle support movement between work locations, while OEM/ODM options let you define the product configuration for your market.
Configuration shown: 220β240V AC, 50/60Hz, with 5 EU AC outlets. Confirm the approved configuration and market-specific requirements before sample approval.
IP54 DUST + SPLASH
BUILT AROUND PROTECTION
The M3003 combines a rugged frame with wheels and a foldable pull handle. Put enclosure protection and practical movement at the center of your product selection.
IP54 means dust-protected and resistant to splashing water. It is not a fully dust-tight, immersion or pressure-washing rating.
Ingress protection is separate from impact resistance. No drop height, crush load, IK rating or military-standard certification is claimed here. Request the model-matched report and applicable operating conditions before final approval.
A Platform for Mobile Work
The M3003 combines a 3072Wh battery with 3000W rated pure sine wave AC output. The published surge specification is 6000VA for up to 200ms; this is not a 6000W continuous-output rating.
Select equipment by its continuous demand and starting characteristics, not by the surge figure alone. Share the proposed load list for a configuration-specific compatibility review.
Rated battery energy
Continuous AC output
Surge β€200ms, not continuous output
Start your load plan with 3072Wh of rated battery energy. Request a load-specific runtime evaluation instead of assuming a fixed operating time for every application.
Wheels and a foldable pull handle support repositioning between work locations. Confirm product dimensions, weight and site access requirements during project review.
Plan Around Your Equipment
Use these applications as starting points for configuration review, not as blanket compatibility guarantees. Submit your equipment list, duty cycle and required backup duration before final selection.

Plan portable power for tool-battery chargers and selected field equipment. Identify starting demand and simultaneous loads before confirming compatibility.

Review computers, communications equipment, selected lighting and production equipment as a combined load. List each device and its operating pattern when requesting a project quotation.

Plan backup for specific equipment within the approved operating limits. Do not assume whole-building coverage, automatic distribution-board integration or uninterrupted operation for every device.
Know the Input Limits
The published configuration accepts AC charging and XT60 solar/DC input, with vehicle charging through an XT60 adapter. Match the charging source to the voltage, current and power limits shown below.
The published AC input is 220β240V, 50/60Hz, up to 2000W, with an approximate charging-time reference of 2 hours. Ask for the relevant starting and ending state of charge, input mode and test conditions before using this timing in your product claims.
The published XT60 input range is 12β60V DC, with a maximum current of 20A and a maximum input power of 1200W. These are input limits, not a promise of constant 1200W charging under all conditions.
Provide panel Voc, Vmp and Isc, the intended series/parallel arrangement and the installation conditions for review. Do not select an array by its wattage alone or assume that AC and solar inputs can be combined without configuration-specific confirmation.
Backup With Defined Limits
The published UPS transfer time is within 20ms, and the EPS maximum load is 3000W. The separate 3220W pass-through rating does not guarantee uninterrupted operation at that load.
Check the connected equipment's interruption tolerance and starting demand before deployment. Do not use the transfer-time figure alone as a guarantee for every server, medical device or other interruption-sensitive load.
Published Configuration Reference
The table describes the published 220β240V configuration, not every possible OEM variant. Confirm the model-specific datasheet and supplied configuration before approving samples or procurement.
| Specification | Published reference |
|---|---|
| Model | iForway M3003 |
| Battery Capacity | 3072Wh (51.2V / 60Ah) |
| Battery Chemistry | LiFePO4 |
| Ingress Protection | IP54: dust-protected and splash-resistant; not for immersion or pressure washing |
| Rated AC Output | 3000W, pure sine wave |
| Surge Rating | 6000VA for up to 200ms; not a continuous-output rating |
| AC Output | 220β240V AC, 50/60Hz |
| AC Outlets | 5 Γ EU AC outlets |
| AC Charging Input | 220β240V AC, 50/60Hz, 2000W max |
| AC Charging-Time Reference | Approximately 2 hours; request applicable test conditions |
| Solar / DC Input | XT60; 12β60V DC; 20A max; 1200W max |
| USB-C Output | 2 Γ PD 100W; 5V/9V/12V/15Vβ3A, 20Vβ5A |
| USB-A Output | 2 Γ QC 3.0 18W; 5Vβ3A, 9Vβ2A, 12Vβ1.5A |
| Car Socket Output | 12V / 10A, 120W |
| Vehicle Charging Input | Up to 120W through an XT60 adapter |
| UPS Transfer-Time Reference | Within 20ms |
| EPS Maximum Load | 3000W |
| Pass-Through Rated Load | 3220W; uninterrupted operation is not guaranteed at this load |
| Display | LCD: battery status, input/output power, remaining time and protection indicators |
| Mobility | Wheels and foldable pull handle |
Individual port ratings do not establish a combined multi-port output rating or combined AC/solar charging capability. Request confirmation for the operating combination required by your project.
Model-Matched Documentation
Tell us the destination market, the required configuration and the documents requested by your customer or compliance team. Ask for model-matched specifications and relevant declarations or reports, and confirm document availability before ordering.
Check the model and configuration covered, the issuer or responsible party, the document or report number, and the version or validity information where applicable. A factory qualification or general standard logo is not a substitute for evidence covering the product configuration you plan to purchase.
Build for Your Brand and Market
Standard OEM MOQ starts at 100 units. Discuss logo, color and packaging requirements first, then separate any firmware, UI, connector or tooling changes into an engineering review.
For standard-platform projects, planning references are approximately 15 days for samples and 35β45 days for mass production after specifications and commercial terms are approved. Engineering changes, tooling, additional testing and material availability can change the schedule, so the confirmed quotation and production plan govern.
A two-year warranty is offered for distributor orders, subject to the agreed warranty terms. Confirm coverage, the warranty start date and the service procedure before placing your order.
Define the market and load: destination, AC requirements, connected equipment and expected order quantity.
Review the configuration: branding scope, engineering changes and required documentation.
Approve the sample and terms: confirm the agreed specification, commercial terms and validation requirements.
Confirm the production plan: agree on the delivery schedule and order-specific requirements.
Choose the Right Platform
Send the required energy capacity, continuous and starting loads, destination market and mobility requirements. Ask our team to review M3003 alongside the appropriate iForway platforms rather than selecting by capacity or peak output alone.
Please include M3003 as the product reference so the enquiry reaches the right configuration discussion. Keep your intended market and order quantity in the same request.
YOUR MARKET. YOUR CONFIGURATION.
Send your destination market, estimated order quantity, required AC configuration and equipment list. Include branding or engineering changes so the enquiry can be reviewed against the correct M3003 configuration.
BEFORE YOU SPECIFY
Clear answers for configuration, procurement and project review.
The M3003 has a rated battery capacity of 3072Wh and 3000W continuous pure sine wave AC output. The published configuration uses a LiFePO4 battery.
No. The published surge specification is 6000VA for up to 200ms, while the continuous AC output rating is 3000W. Confirm the starting characteristics of the proposed equipment before selection.
The published solar/DC input is XT60, 12β60V DC, 20A maximum and 1200W maximum. Provide the panel specifications and array connection plan for compatibility review before connecting a solar array.
The published reference is approximately 2 hours, with AC input rated up to 2000W for the 220β240V configuration. Request the applicable test conditions before using this figure in a specification or performance claim.
Do not assume zero interruption: the published transfer-time reference is within 20ms, with an EPS maximum load of 3000W. The separate 3220W pass-through rating does not guarantee uninterrupted operation at that load, so connected-equipment requirements must be checked.
This page describes a 220β240V AC, 50/60Hz configuration with 5 EU AC outlets. Do not assume that this specification covers a 120V version or every regional outlet option; confirm the required supplied version in writing.
Send the equipment list, operating pattern and required backup duration so the project can be evaluated against the intended configuration. Ask whether any runtime figure supplied is a measured result or an estimate, and review the conditions attached to it.
Standard OEM MOQ starts at 100 units. Submit your configuration and branding requirements so the quotation can define the order scope.
Discuss logo, color and packaging requirements for the M3003 platform, and identify any firmware, UI, connector or tooling changes separately. Engineering-dependent changes require a feasibility and validation review before being confirmed in the quotation.
For standard-platform projects, planning references are approximately 15 days for samples and 35β45 days for mass production after specifications and commercial terms are approved. The quotation and production plan confirm the schedule, especially where engineering changes, tooling, testing or material availability are involved.
The published distributor warranty is two years, subject to the agreed warranty terms. Confirm coverage, the start date and the service procedure before ordering.
Specify the destination market and exact M3003 configuration, then request the applicable document list and confirm availability. Check the model coverage, responsible party, document numbers and version or validity details rather than relying on a general logo or a different model's documents.
The M3003 is specified with an IP54 ingress-protection rating: dust-protected and resistant to splashing water. This does not mean fully dust-tight, submersible or suitable for pressure washing. IP54 is not an impact or drop-test rating. Request the model-matched test report and operating conditions before final project approval.